Skip to main content

Table 5 Statistical characteristics of measured ultrasound parameters in predicting difficult intubation

From: Prediction of difficult laryngoscopy / difficult intubation cases using upper airway ultrasound measurements in emergency department: a prospective observational study

Variable

Number of laryngoscopy attempts

p

< 3

≥ 3

Mean ± SD / number (%)

HBV

  

0.004

Yes

109 (91.6%)

1 (25%)

No

10 (8.4%)

3 (75%)

DSHB (mm)

8.75 ± 2.02

9.74 ± 1.05

0.629

DSVC (mm)

7.66 ± 1.87

9.81 ± 1.54

0.025

DSTI (mm)

8.85 ± 2.24

12.78 ± 1.85

0.001

DBAC (mm)

6.43 ± 1.64

6.96 ± 1.48

0.526

  1. HBV: Hyoid Bone Visibility. DSHB: Distance from Skin to Hyoid Bone. DSVC: Distance from Skin to Vocal Cords. DSTI: Distance from Skin to Thyroid Isthmus. DBAC: Distance between Arytenoids Cartilages