Figure 3 | BMC Emergency Medicine

Figure 3

From: Factors affecting pediatric isotonic fluid resuscitation efficiency: a randomized controlled trial evaluating the impact of syringe size

Figure 3

Preferred techniques of rapid fluid resuscitation as reported by participants. The majority of respondents reported preference for the ‘disconnect-reconnect’ technique of fluid bolusing. The next most commonly cited preference was the ‘push-pull’ technique, and 8/48 participants reported preference for a regular infusion pump – an unacceptable means of delivering a fluid bolus in a resuscitation scenario. Legend: gray, Pressure bag; red, Disconnect-Reconnect technique; green, Push-Pull technique; violet, Regular infusion pump; blue, Don’t know/no answer; orange, More than one preferred technique.