Table 3 Descriptions of Pre-hospital Imaging Technologies and Outcomes

From: A scoping review of pre-hospital technology to assist ambulance personnel with patient diagnosis or stratification during the emergency assessment of suspected stroke

Study Details

Portability and Resolution

Expertise and training requirements

Person interpreting output

Location (on scene; stationary ambulance; in transit)

Purpose, Diagnostic accuracy, comparator and clinical scale

Physical

invasiveness and time to acquire results

Acceptability: clinicians and/or patients

Impact on EMS clinician decisions or treatment provision

Impact on process (time metrics) or patient outcomes

Costs

“Handheld Infra-red screening device”

Murphy et al. 2015 [24]

Electromagnetic Spectroscopy – Light

FDA approved

CE Marked

ISO certificatio

Portability:

Highly portable (hand-held)

Resolution:

Low resolution

Expertise:

Qualified Paramedic

Training:

required

EMS clinician

In transit

Purpose: Diagnostic

-Stroke

-Mimic

-Haemorrhage

Diagnostic accuracy:

Haemorrhage vs Mimic

False Positive Rate: 15

False Negative Rate: 2

True Positive Rate: 5

True Negative Rate: 10      Extrapolated Values:    Sensitivity:  71% Specificity: 40%

Haemorrhage vs Ischaemia

False Positive Rate: 8

False Negative Rate: 2

True Positive Rate: 5

True Negative Rate: 6   Extrapolated Values:                            Sensitivity: 71%  Specificity: 42%

Comparator: CT (hospital) scan

Clinical scale: stroke assessment form

Non-invasive

Time to acquire results:

2–3 min

Clinicians:

2–3 min too long (+increased FPR if time reduced).

Measurements performed during fast ambulance transport appeared to cause false positive readings

Unreliable measurement for combative and epileptic patients.

Destination:

None

Treatment:

Not reported

Not reported

Not reported

Electra-Stroke

Coutinho 2019 [25]

EEG

Waveguard™ dry electrode cap and the eego™ amplifier are both CE marked

Portability:

Portable with use of a vehicle

Resolution:

Low Resolution

Expertise:

Qualified paramedic

Training:

Not reported

Unclear

In transit

Other locations unclear

Purpose: Diagnostic

-LVO-a

Diagnostic accuracy:

Results not yet available

Comparator: Final (hospital) diagnosis

Clinical scale: mRS, NIHSS

Non-invasive

Time to acquire results:

‘Under 5 min’

Results not yet available

Destination:

Results not yet available

Treatment: Results not yet available

Results not yet available

Not reported