Skip to main content

Table 3 Multilevel models parameter estimates for ambient noise level LAeq

From: Impact of a visual indicator on the noise level in an emergency medical dispatch centre - a pilot study

 

Model 1

Model 2

Model 3

β

95%CI

P

β

95%CI

P

β

95%CI

P

Fixed Part

         

Intercept

58.93

  

56.83

  

56.8

  

Intervention effect

 Phase 1 (without visual signal)

Ref

 

< 10−3

Ref

 

< 10−3

  

< 10−3

 Phase 2 (with visual signal)

−4.28

[−5.04; − 3.52]

 

−4.19

[−4.63; − 3.74]

 

− 4.19

[− 4.63; − 3.75]

 

Period

 Night (09:00 PM – 07:00 AM)

   

Ref

 

< 10− 3

Ref

 

< 10− 3

 Day (07:00 AM – 09:00 PM)

   

1.51

[1.17; 1.85]

 

1.53

[1.19; 1.87]

 

Number of calls per minute

 0

   

Ref

 

0.74

  

0.97

 1–2

   

−0.03

[−0.22; 0.17]

 

0.03

[−0.25; 0.31]

 

 ≥ 3

   

0.06

[−0.2; 0.31]

 

0,00

[−0.58; 0.58]

 

Number EMDC workers

 8–9

   

Ref

 

< 10−3

  

< 10− 3

 10–17

   

1.41

[0.88; 1.94]

 

1.36

[0.77; 1.95]

 

 18–20

   

1.72

[0.79; 2.64]

 

2.76

[1.6; 3.92]

 

Tnteraction between the number of calls per minute and the number of EMDC workers

      

Ref

  

0 call per minute

        

0.04

1–2 calls per minute / 10–17 workers

      

−0.01

[−0.41; 0.39]

 

≥ 3 calls per minute / 10–17 workers

      

0.24

[−0.43; 0.90]

 

1–2 calls per minute / 18–20 workers

      

−1.1

[−1.97; −0.22]

 

≥ 3 calls per minute / 18–20 workers

      

−1.16

[−2.16; −0.16]

 

Random Part

Level2: Time block

1.58

  

0.39

  

0.38

  

Level1: Minute

13.93

  

13.88

  

13.87

  

−2*loglikelihood:

47,398.11

  

47,308.62

  

47,298.37

  

Units: Time block

46

  

46

  

46

  

Units: Minute

8640

  

8640

  

8640

  
  1. CI Confidence Interval